Product Description
Arctic Ultraflex Blue®
Single Conductor Wire
4 AWG Green with Yellow Extruded Stripe
Legend:
E196955 4 AWM AWG OIL RESISTANT 600V VW-1 ARCTIC ULTRAFLEX BLUE® -55°C TO 105°C CSA 234608 TEW 105°C 600V FT1
Rated for and proven in extreme temperatures of -55°C to 105°C
This highly flexible wire combines finely stranded copper with a jacket that resists the abuses of oil, gasoline, sunlight, saltwater, acids, and chemicals. Arctic Ultraflex Blue® has high abrasion resistance and can be used in most 600V applications. UL Listed as AWM (Appliance Wiring Material). Numerous applications including those approved under NEC article 400 and associated articles.
Features:
- Superior flexibility to -55°C (-67°F)
- Class K fine stranded copper construction
- Resists oil, grease, chemicals, abrasion
- Sunlight and weather resistant
- Flame retardant (VW-1)
- UL Recognized and CSA Approved
- Environmentally safe
- Made in the USA
Applications:
- UL 508A Industrial control panels
- Internal appliance and equipment wiring
- Inverter cables and wiring
- Industrial machines and robotics
- Construction equipment
- Marine, RV and automotive wiring
- Medium and heavy-duty trucks and trailers
- Load banks, motor leads, welding cable
- Forklifts and golf carts
- Batteries and chargers
- Power hookup cable
Manufactured exclusively by Polar Wire Products
-55°C to 105°C
Construction Specifications:
- 4 AWG
- Class K Copper Stranding (420/30)
- .240" Conductor Outside Diameter
- .060" Insulation Thickness
- .360" Finished Outside Diameter
- Ampacity at 30°C (86°F)*: 150
- Ampacity at 40°C (104°F)*: 142
Insulation Properties | Test Method | Performance |
---|---|---|
Specific Gravity (±.02) | ASTM D-792 | 1.30 |
Durometer Shore 'A' (±.02) INST./15 seconds | ASTM D-2240 | 77/65 |
Tensile Strength (60 mil) | ASTM D-412 | 2000 |
Elongation % | ASTM D-412 | 300 |
Brittle Point (C) | ASTM D-746 | -55°C |
Oxygen Index % | ASTM D-2863 | 25.0 |
Oil Aged 18 Hours @ 121°C % Retention of Tensiles % Retention of Elongation | UL Standard UL Standard | 129% 72% |
Air Aged 7 Days @ 136°C % Retention of Tensiles % Retention of Elongation | ASTM D412-80 ASTM D412-80 | 109% 100% |
Oil Aged 7 Days @ 60°C % Retention of Tensiles % Retention of Elongation | ASTM D412-80 ASTM D412-80 | 124% 89% |
VW-1 Flame Test | UL Standard | Pass |
Product Cold Bend Test | UL Standard | Pass |
Voltage Rating | UL Standard | 600 |
*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors.
Legend:E196955 AWM 4 AWG OIL RESISTANT 600V VW-1 ARCTIC ULTRAFLEX BLUE® -55°C TO 105°C CSA 234608 TEW 105°C 600V FT1 Rated for and proven in extreme temperatures of -55°C to 105°C This highly flexible wire combines finely stranded copper with a jacket that resists the abuses of oil, gasoline, sunlight, saltwater, acids, and chemicals. ARCTIC ULTRAFLEX BLUE® has high abrasion resistance and can be used in most 600V applications. UL Listed as AWM (Appliance Wiring Material). Numerous applications including those approved under NEC article 400 and associated articles. Features: Superior flexibility to -55°C (-67°F) Class K fine stranded copper construction Resists oil, grease, chemicals, abrasion Sunlight and weather resistant Flame retardant (VW-1) UL Recognized and CSA Approved Environmentally safe Made in the USA Applications: UL 508A Industrial control panels Internal appliance and equipment wiring Inverter cables and wiring Industrial machines and robotics Construction equipment Marine, RV and automotive wiring Medium and heavy-duty trucks and trailers Load banks, motor leads, welding cable Forklifts and golf carts Batteries and chargers Power hookup cable Manufactured exclusivelyby Polar Wire Products -55°C to 105°C Construction Specifications: 4 AWG Class K Copper Stranding (420/30) .240" Conductor Outside Diameter .060" Insulation Thickness .360" Finished Outside Diameter Ampacity at 30°C (86°F)*: 150 Ampacity at 40°C (104°F)*: 142*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors. Insulation PropertiesTest MethodPerformance Specific Gravity (±.02) ASTM D-792 1.30 Durometer Shore 'A'(±.02) INST./15 seconds ASTM D-2240 77/65 Tensile Strength (60 mil) ASTM D-412 2000 Elongation % ASTM D-412 300 Brittle Point (C) ASTM D-746 -55°C Oxygen Index % ASTM D-2863 25.0 Oil Aged 18 Hours @ 121°C% Retention of Tensiles% Retention of Elongation UL StandardUL Standard 129%72% Air Aged 7 Days @ 136°C% Retention of Tensiles% Retention of Elongation ASTM D412-80ASTM D412-80 109%100% Oil Aged 7 Days @ 60°C% Retention of Tensiles% Retention of Elongation ASTM D412-80ASTM D412-80 124%89% VW-1 Flame Test UL Standard Pass Product Cold Bend Test UL Standard Pass Voltage Rating UL Standard 600