Product Description
Arctic Ultraflex Blue®
Power Cord
6 AWG
4 Conductors: Black, White, Red, and Green
Legend:
ARCTIC ULTRAFLEX BLUE® E224869 6 AWG (13.3mm2) 4/C SEOOW (UL) 600V 105C (-50C) CSA 265576 SEOOW 600V 105C (-50C) FT2 WATER RESISTANT
Rated for and proven in extreme temperatures of -50°C to 105°C
Arctic Ultraflex Blue® Power Cord is rated for temperatures as low as 50°C. The tough, flexible jacket and finely stranded 100% copper conductors give our power cord superior durability and workability in even the harshest conditions.
Features:
- Flexible, tough Arctic Ultraflex Blue® jacket
- Works under temperature extremes of -50°C to 105°C
- Color coded conductors for easy identification
- Excellent abrasion and cut resistance
- Ozone, sunlight, oil, and water resistant with high dielectric insulation
- Water and mold resistant non-wicking polypropylene fillers
- Lightweight, long lasting, easy to carry and handle
- All components are recyclable and non-hazardous for environmental landfill disposal
- Environmentally safe
- Made in the USA
-50°C to 105°C
Applications:
- Special uses requiring flexibility and mechanical toughness, high environmental resistance and flame retardance
- Pendant push button remote controls
- Motor control, stage equipment and lighting
- Industrial control and robotic systems
- Machine and power tools
- Portable power
- Dockside power applications
- Mining and outdoor applications
- Suitable and approved for temporary submersion in water
Industry Approvals:
- Federal and Military use under Federal Spec. JC-580B
- UL Listed SEOOW 600V for NEC Article 400
- UL Standard UL 62
- UL Horizontal Flame
- CSA Certified STOOW (TPE) -50°C to 105°C
- MSHA approval for flame resistance and mining applications
Construction Specifications:
- 6 AWG
- 4 Conductors: Black, White, Red and Green
- Class K Stranded 7x37/30 Bare Copper
- Conductor DCR 0.4 Ω/M
- Nominal Outside Diameter 1.038″ (26.37mm)
- 45 Amps**
- TPE Insulation
- Polypropylene Fillers
Manufactured exclusively by Polar Wire Products
Sizes and Configurations:
600V Power Cord
Part Number
of Conductors
Quantity/AWG
Diameter
AMPS*
300V Junior Power Cord
Part Number
of Conductors
Quantity/AWG
Diameter
AMPS*
*Ampacity based on NEC Table 400.5 (A) and CEC Table 12. The ampacity chart is provided for engineering information only. Polar Wire Products cannot recommend or express the use of these ampacities since the exact application may need approval from the authority having local jurisdiction.
This information is subject to engineering changes. Cold temperature rating is -50°C.