THHW/TEW/MTW/AWM/BC-5W2/SAE TYPE SGT/CT
Multi Listed Flexible Wire
1/0 AWG
Legend: E312440 1/0 AWG 53.50mm2) 600 VOLT (UL) TYPE MTW VW-1 OR THHW FOR CT USE OR BOAT CABLE BC-5W2 OR AWM STYLES 1232/1284/1338/10269 . . . CSA 234608 TEW 105°C 600V FT1 OR AWM I A/B 600 VOLT 105°C 600V FT1 . . . FOR SAE TYPE SGT
Polar Wire combines finely stranded annealed copper conductors with an extra-flexible, fire retardant PVC jacket for a multipurpose flexible wire that handles better, reduces installation effort, and performs to the highest standards
Single Conductor Multi Listed Flexible Wire is a Class K flexing service wire made with 30 AWG fine conductor stranding for superior flexibility. Constructed of soft annealed bare copper (NO ALUMINUM!) to ASTM Specification B172. Insulated with an extra-flexible extruded, high dielectric PVC jacket that resists abrasion, oils, acids, heat, flame, and moisture, and performs reliably in severe cold temperatures and high heat conditions.
THHW/TEW/MTW/AWM/BC-5W2/SAE TYPE SGT/CT Multi Listed Flexible Wire holds multiple ratings and certifications:
![]()
Multi Listed Flexible Wire (THHW)
Features:
Applications:
Industry Approvals:
![]()
-40°C to 105°C
Construction Specifications:
Class K Finely Stranded Multi Listed Flexible Wire
*Available by special order, minimums may apply
**The ampacities provided are for informational purposes only. Acceptance of these values by any governing body is the responsibility of the end user. Ampacities are based on a single conductor, in free air, at 30°C ambient air temperature. 105°C ampacities adapted from ICEA P-54-440/NEMA WC51-1986 R1991)


THHW-1/0
Bare Copper
Class K (1064/30)
.080"
.655"
1/0 AWG
1
1 lb
260*
230*
-40°F to 221°F (-40°C to 105°C)
600V
*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors.
Item Number: THHW-1/0BLK
Fri, Sep 4 - Tue, Sep 8
Order within 17m
Polar Wire
Item Number: THHW-1/0BLK
WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

Fri, Sep 4 - Tue, Sep 8
Order within 17m
THHW-1/0
Bare Copper
Class K (1064/30)
.080"
.655"
1/0 AWG
1
1 lb
260*
230*
-40°F to 221°F (-40°C to 105°C)
600V
*Ampacities of 600V and 1000V 105°C AWM wires in air. Ampacities based on single conductor in free air, 30°C or 40°C ambient temperature as specified, 105°C conductor temperature, per NEC table 310-17 (adjusted for 105°C). Free air ratings assume a one-cable-diameter space between adjacent conductors.
THHW/TEW/MTW/AWM/BC-5W2/SAE TYPE SGT/CT
Multi Listed Flexible Wire
1/0 AWG
Legend: E312440 1/0 AWG 53.50mm2) 600 VOLT (UL) TYPE MTW VW-1 OR THHW FOR CT USE OR BOAT CABLE BC-5W2 OR AWM STYLES 1232/1284/1338/10269 . . . CSA 234608 TEW 105°C 600V FT1 OR AWM I A/B 600 VOLT 105°C 600V FT1 . . . FOR SAE TYPE SGT
Polar Wire combines finely stranded annealed copper conductors with an extra-flexible, fire retardant PVC jacket for a multipurpose flexible wire that handles better, reduces installation effort, and performs to the highest standards
Single Conductor Multi Listed Flexible Wire is a Class K flexing service wire made with 30 AWG fine conductor stranding for superior flexibility. Constructed of soft annealed bare copper (NO ALUMINUM!) to ASTM Specification B172. Insulated with an extra-flexible extruded, high dielectric PVC jacket that resists abrasion, oils, acids, heat, flame, and moisture, and performs reliably in severe cold temperatures and high heat conditions.
THHW/TEW/MTW/AWM/BC-5W2/SAE TYPE SGT/CT Multi Listed Flexible Wire holds multiple ratings and certifications:
![]()
Multi Listed Flexible Wire (THHW)
Features:
Applications:
Industry Approvals:
![]()
-40°C to 105°C
Construction Specifications:
Class K Finely Stranded Multi Listed Flexible Wire
*Available by special order, minimums may apply
**The ampacities provided are for informational purposes only. Acceptance of these values by any governing body is the responsibility of the end user. Ampacities are based on a single conductor, in free air, at 30°C ambient air temperature. 105°C ampacities adapted from ICEA P-54-440/NEMA WC51-1986 R1991)

ArrivesFri, Sep 4 - Tue, Sep 8

ArrivesFri, Sep 4 - Tue, Sep 8

ArrivesFri, Sep 4 - Tue, Sep 8

ArrivesFri, Sep 4 - Tue, Sep 8

ArrivesFri, Sep 4 - Tue, Sep 8